Part Number: TT1-10835 | Alternate P/N: TT110835 | Manufacturer: Transformer Technicians Inc |
NSN : 5950-00-279-4018 | Item Name : transformer power | CAGE Code : 96253 |
FSC : 5950 Coils and Transformers |
Hardware Orbit is your premier supplier for top-quality NSN parts and components, offering competitive pricing and rapid lead times on numerous items such as NSN 5950-00-279-4018 with the part number TT1-10835. This particular NSN is described as a Transformer Power, and it was manufactured by Transformer Technicians Inc. As we currently have this item readily available for purchase at any time, we invite you to request a quote for your comparisons through the completion of the RFQ form provided below. As our team of industry experts is always readily available for customer needs 24/7/365, responses to quote requests for part number TT1-10835 will be given in just 15 minutes or less upon the receipt of a completed form.
Whether you require an NSN 5950-00-279-4018 and part number like TT1-10835 or other various items from the CAGE Code 96253 or Transformer Technicians Inc, we have you covered with an unrivaled inventory of items. National Stock Numbers, more commonly known as NSNs, are 13-digit numeric codes recognized by NATO countries for the identification of "standardized material items of supply." Broken into separate groups, the numbers of the NSN may be used to identify the country that codified the item, the group and class that the item belongs to, and the specific item itself. When you are in the market for various NSN parts, take advantage of our included search engine and filters to find results in a matter of moments.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-279-4018 Item Description: Transformer Power | 5950 | 002794018 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Tt1-10835 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.940 INCHES MAXIMUM3.940 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.970 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.970 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.030 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.030 INCHES MAXIMUM SINGLE MOUNTIN |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.350 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.350 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.410 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.410 INCHES MAXIMUM SINGLE MOUNTIN |
ABMK | OVERALL WIDTH | 2.120 INCHES MAXIMUM2.120 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-WYEWYE-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.940 INCHES MAXIMUM3.940 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT9 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 150.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 185.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 300.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 236.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY130.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY236.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 236.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY552.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 236.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY130.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 552.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 552.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY236.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY236.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING; 9 SECONDARY WINDINGS |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 27 STANDOFF, SOLDER LUG |
FSC 2030 Deck Machinery |
FSC 2630 Tires Solid And Cushion |
FSC 1630 Aircraft Wheel And Brake Systems |
FSC 2815 Diesel Engines And Components |
FSC 2950 Turbosupercharger And Components |
View All |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote